Saltar al contenido principal
Axon Group

AG Products

AG Test6

Simulate, diagnose, and test communications from the substation to the control center: ICCP, IEC 61850, telecontrol, and IEC 61131-3 logic, all from a single computer.

Protocols ICCP/TASE.2 · IEC 61850 · IEC 60870-5-104 and 101 · DNP3 · Modbus · OPC UA · SNMP · SNTP · PTP

Overview

All your communication tests,
in a single tool

AG Test6 simulates both ends of every link: clients and servers, masters and slaves, publishers and subscribers. You test control centers over ICCP, IEC 61850 digital substations, and telecontrol, with IEC 61131-3 logic that reacts like the real equipment and an Automated Test that delivers the test report ready to sign.

One project, one interface, and a modular license: you activate only what you need.

AG Test6 start screen with recent projects and the templates for each protocol: ICCP, IEC 61850, GOOSE, Sampled Values, IEC 101 and 104, DNP3, Modbus, OPC UA, and SNMP
Software

Twelve protocols and four test tools, in one project

Modules

Module gallery

Open clients and masters, servers and slaves, and tools from a single gallery. Each module is configured within the same project, with its connections, signals, and mappings.

SCL editor

Edit and validate your SCL files

Open ICD, CID, SCD, or SSD files, review the IEC 61850 model, and validate it per IEC 61850-6 before loading it into a simulated server.

Virtual PLC

IEC 61131-3 logic without hardware

Program interlocking and sequences in ST, IL, LD, FBD, or SFC and connect them to the signals and controls of the project protocols.

Automated Test

FAT/SAT campaigns with a test report

Design the plan once, run it as many times as needed, and deliver a test report with a verdict, per-signal detail, and SHA-256 fingerprint.

Scripting

Positive and negative tests

Build frames by hand, bypassing the protocol state machine, to recreate unique scenarios and see how the device responds.

AG Test6 module gallery with clients, slaves, and tools
AG Test6 SCL editor with the model of an IED
AG Test6 virtual PLC with an IEC 61131-3 program
Summary of an AG Test6 Automated Test campaign
AG Test6 scripting editor with its log
Interoperability

Twelve protocols, both ends of each one

From the control center to the bay: AG Test6 simulates the side you are missing so you can test the device or system in front of you. Security with TLS in DNP3, Modbus, IEC 104, and ICCP; Secure Authentication in DNP3; X.509 certificates in OPC UA.

IEDs, RTUs, and gateways

Devices under test

Simulates, diagnoses, and tests

SCADA and control centers

System under test

ICCP / TASE.2

Exchange between control centers (IEC 60870-6), blocks 1 to 5. Simple or bilateral association and optional IEC 62351-3 TLS.

ClientServer

IEC 61850 MMS

MMS client and server: attributes, datasets, controls, setting groups, and reports (beta on the server).

ClientServer

IEC 61850 GOOSE

Publishing and subscribing to GOOSE messages, with the Ed. 2 simulation bit.

PublisherSubscriber

IEC 61850 Sampled Values

80 samples per cycle: 4,000 sps at 50 Hz and 4,800 sps at 60 Hz.

PublisherSubscriber

IEC 60870-5-104

Telecontrol over TCP/IP: monitoring, control, system, and files, with multi-master redundancy.

MasterSlave

IEC 60870-5-101

Telecontrol over a serial port, at both ends.

MasterSlave

DNP3

Over TCP (with or without TLS) or over a serial port, with Secure Authentication.

MasterOutstation

Modbus

TCP (with or without TLS) or serial, for meters, PLCs, and field devices.

ClientServer

OPC UA

Interoperability with an address space and X.509 certificates.

ClientServer

SNMP

Network management: query and simulate communications equipment.

ManagerAgent

SNTP

Network time synchronization.

ClientServer

PTP IEC 61850-9-3

Precision time for the digital substation.

SlaveMaster

SCL Editor

IEC 61850-6 editing and validation.

Tool

Virtual PLC

IEC 61131-3 logic connected to the protocols.

Tool

Automated Test

FAT/SAT plans with a test report ready to sign.

Tool

Scripting

Positive and negative tests, frame by frame.

Tool

Also, axon-bay: a free bay simulator to practice without equipment.

Who it is for

Who is AG Test6 for?

  • Control centers

    Network operators and control centers

    Test ICCP links between centers before connecting them, with the client and server simulated on the same computer.

  • Digital substation

    IEC 61850 integrators

    Load the SCL, simulate the IEDs you do not have yet, and verify GOOSE, Sampled Values, and controls.

  • Testing

    FAT and SAT test engineers

    Design the campaign once and deliver a test report ready to sign with every test.

  • Training

    Laboratories and training

    Show how each protocol behaves, frame by frame, and create positive and negative scenarios with scripts.

  • Your project

    Is your case different?

    Tell us what you need to test and we will show you how to do it with AG Test6.

ICCP / TASE.2

Exchange between control centers, at both ends

ICCP client and server with TASE.2 blocks 1 to 5, to test links between control centers before connecting them.

AG Test6 ICCP viewer with the exchanged objects
AG Test6 ICCP viewer with the objects exchanged between the two simulated control centers.

5TASE.2 blocks, from basic data exchange to device control

  1. Simulated client and server

    Simulate the missing control center and test the one in the system under test, over a single MMS association.

  2. Association modes

    Simple, active bilateral, or passive bilateral, depending on how the link is agreed.

  3. Optional security

    TLS per IEC 62351-3 when the link requires it.

Configuration templates for quick tests: start from ready-made examples of typical configurations and adjust them to your link.

IEC 61850

The digital substation, from model to control

Load the SCL, simulate the IEDs you do not have yet, and verify MMS, GOOSE, and Sampled Values from the same project.

MMS client and server

Connect to a real IED as a client or start a server from the SCL to test the system that queries it.

  • Read and write attributes and datasets
  • Controls with orCat, test bit, and interlocking and synchrocheck verification
  • Server with datasets, controls, and setting groups
  • Reports from the SCL model (beta)
  • GOOSE and Sampled Values as publisher and subscriber, with the IEC 61850-8-1 Ed. 2 simulation bit
  • SCL editor with IEC 61850-6 validation
Simulated IEC 61850 server in AG Test6
Logic · IEC 61131-3

A virtual PLC wired to the protocols

Emulate interlocking, signal transformations, and sequences of an RTU or a PLC without hardware, and have the device under test interact with them.

Five languages, one project

Program in structured text (ST), instruction list (IL), ladder diagram (LD), function block diagram (FBD), or sequential function chart (SFC). The logic is saved with the project: when you open it, programs, variables, tasks, and mappings are ready.

  • I/O map: link %I and %Q to the signals and controls of the masters
  • Event-driven tasks: a control that reaches a slave triggers the logic
  • Publish global variables to the slaves and servers
  • Check, simulate step by step, and run with live counters
AG Test6 virtual PLC with an IEC 61131-3 program
Automated Test

From test plan to test report ready to sign

What you do a hundred times in a FAT, AG Test6 does for you: the same every time and with the test report at the end.

FAT/SAT plans

Steps, signals, and expected responses in a plan that you run as many times as needed.

460

Conformance rules included

Ready-made checks for the project protocols.

Unattended too

The same campaign runs without an interface from continuous integration and leaves the test report in the run folder.

A test report you can sign

When the campaign ends, AG Test6 builds the test report with everything that happened, ready to review and sign.

  • Verdict and availability of the campaign
  • Detail by signal and by step
  • Open items to close in the next run
  • SHA-256 fingerprint that guarantees the test report was not altered
  • Signature block
  • 61850 → 104 gateways (beta)
Summary of an AG Test6 Automated Test campaign
Scripting

Positive and negative tests, frame by frame

Build the frames by hand, bypassing the protocol state machine. This way you recreate unique scenarios and see how the device responds when something does not go as expected.

AG Test6 scripting editor with its log
AG Test6 scripting editor with the execution log.

+/−positive tests, to confirm the device does what it should, and negative tests, to see what it does when it receives what it should not

  1. Custom frames

    Build each message field by field and send it in the order you want.

  2. Repeatable scenarios

    Save the script and run it again on every version of the device or firmware.

  3. Execution log

    Every step is recorded with what was sent and received.

Trace and Log always at hand: follow the frame exchange while the script runs.

AI integration · MCP

Ask your test bench

AG Test6 exposes the test session through the MCP protocol, so you can query it from your AI assistant in natural language.

Your assistant, connected to the session

MCP clients such as Claude Desktop, Claude Code, or VS Code can read the state of the test session and help you interpret it.

  • Query the state of the modules and signals
  • Ask for a summary of what happened in the test
  • Secrets hidden in Trace and Log
An AI assistant queries the AG Test6 session over MCP and summarizes the IEC 61850 model discovered in an IED: logical devices, datasets, reports, and controls
Specifications and requirements

What AG Test6 includes and what your computer needs

Modular license and requirements of the computer where it is installed.

License

Modular

  • License file (node-locked)
  • USB
  • HASP / KeyLok key

Buy only the protocols and tools you need. Coming from Axon AT5, the previous version? Your license is still valid.

Try it before you buy

Demo and evaluation

  • Demo with all modules, 10 min per session
  • Temporary evaluation licenses
  • 11 templates

Start testing from day one with the included templates.

Computer requirements 10 requirements
  • Operating system

    Windows 10 / 11

    64-bit · administrator to install

  • Processor

    2 cores

    Minimum · 4 or more recommended

  • RAM

    4 GB

    Minimum · 8 GB recommended

  • Disk

    1 GB free

    Minimum · 2 GB for projects and captures

  • Graphics

    No GPU required

    Software rendering included

  • GOOSE, SV, and PTP

    Physical Ethernet card

    Axon NDIS service included in the installer

  • Serial ports

    Serial port or adapter

    For IEC 101, DNP3, and Modbus

  • License keys

    HASP or KeyLok

    Manufacturer drivers, not included

  • Languages

    Spanish and English

    Interface

  • Internet

    Not required

    Works offline

Questions about your infrastructure? Our team reviews your computer with you before installation.

Support and questions

We are with you before and after purchase

Technical support in Spanish from engineers specialized in ICCP, IEC 61850, and telecontrol.

Which protocols does it simulate?

ICCP/TASE.2, IEC 61850 (MMS, GOOSE, and Sampled Values), IEC 60870-5-104 and 101, DNP3, Modbus, OPC UA, SNMP, SNTP, and PTP, each at both ends. See protocols ›

Can it be an ICCP client and server at the same time?

Yes. It simulates both control centers, with simple or bilateral association and optional TLS. See ICCP ›

Does it generate test reports?

Yes. The Automated Test delivers a test report with a verdict, detail by signal and by step, open items, a SHA-256 fingerprint, and signatures. See Automated Test ›

How is it licensed?

With a modular license as a node-locked license file, USB, or HASP / KeyLok key. If you are coming from Axon AT5, your license is still valid. See requirements ›

Can I try it before deciding?

Yes. Demo mode opens all modules for 10 minutes per session, and temporary evaluation licenses are available. Request a demo ›

Do you offer training?

Yes, with AG Empowering: IEC 61850, IEC 60870-5-104, DNP3, digital substations, and OT networks. See programs ›

Direct purchase

Buy AG Test6 online

Start from the base and add the protocols and tools you need. Prices in USD per license.

AG Test BaseIncluded in every purchase
ProtocolsOptional · one or several
IEC 61850 modulesOptional · the full suite includes the Automated Test
ToolsOptional
License typeChoose one

Number of licensesOne per test computer

Request a demonstration

See AG Test6 with your own equipment

  • ICCP, IEC 61850, telecontrol, and logic working together
  • From simulation to the test report ready to sign
  • Evaluation licenses to test on your bench
AG Test6 screenshots: ICCP client viewer and module gallery
More AG products

Explore other AG products

1–3 of 4